40W Explosion Proof LED Linear Light, 5000K, 2 ft, 100–277V AC
LUMENS—
WATTAGE40W
VOLTAGE100–277V AC
CCT—
WARRANTY—
SKU: EX-40W FLF2D50D12027 5000K ● In stock

40W Explosion Proof LED Linear Light, 5000K, 2 ft, 100–277V AC

DIRECT PRICE $290.00
● Dallas, TX & LA, CA Hubs · Ships in 24h
Bulk Savings 10% at $1,000+ · 14% at $3,000+ · 17% at $5,000+ · 20% at $8,000+
Item total: $290.00

Displayed volume savings are estimates. Final discounts, shipping and tax are confirmed in the cart or at checkout. Discounts may not combine with other offers.

40W Explosion Proof LED Linear Light – 5000K, 2 ft

The JCELighting EX-40W FLF2D50D12027 is a 40W explosion proof LED linear light designed for compatible hazardous-location lighting projects. It features a 5000K color temperature, 100–277V AC input, 0–10V dimming, a 120° beam angle, and a Mean Well LED driver.

With a compact 2 ft form factor, a PC lens, two-end junction box configuration, and wall-mount installation, this fixture is designed for industrial lighting applications that require verified hazardous-location ratings and durable enclosure performance. The specified luminous efficacy is 140 lm/W.

Key Features

  • 40W LED Lighting: A compact linear lighting solution for compatible industrial projects.
  • 5000K Color Temperature: Provides cool white illumination.
  • 100–277V AC Input: For compatible electrical systems within the specified voltage range.
  • 0–10V Dimming: Supports compatible dimming controls.
  • 120° Beam Angle: Provides broad light distribution.
  • Mean Well Driver: Equipped with a Mean Well LED driver.
  • 2 ft Linear Design: Suitable for projects specifying a compact linear fixture.
  • PC Lens: Features a polycarbonate lens.
  • Two-End Junction Boxes: Configured with junction boxes at both ends.
  • Wall-Mount Installation: Designed for wall mounting.
  • 140 lm/W Luminous Efficacy: Specified luminous efficacy of 140 lumens per watt.
  • IP66 Rating: Rated IP66 according to the supplied product specifications.
  • IK10 Rating: Rated IK10 according to the supplied product specifications.
  • 500-Hour Salt Spray Test: Specified as tested for 500 hours of salt spray exposure.

Hazardous Location Ratings

The supplied specifications identify this model for Class I, Division 2, Groups A, B, C, and D, and Class I, Zone 2, Group IIC. Verify the product marking, applicable certification records, installation instructions, and site classification before specifying or installing the fixture.

Certifications and Standards

  • UL 844 – Luminaires for Use in Hazardous (Classified) Locations
  • UL 924 – Emergency Lighting and Power Equipment; the exact applicability to this model and any associated emergency-lighting functionality require verification.
  • CSA C22.2 No. 141-15, Edition 5
  • CSA C22.2 No. 137:2018, Edition 2
  • ETL
  • ABS

Refer to the applicable product labels and certification documentation for the exact standards, ratings, and intended uses covered by each listing. Do not assume that UL 924 indicates an integral battery or emergency operation unless confirmed in the product documentation.

Technical Specifications

Model EX-40W FLF2D50D12027 5000K
Wattage 40W
Color Temperature 5000K
Input Voltage 100–277V AC
Length 2 ft
LED Type 5050 LEDs
Dimming 0–10V
Beam Angle 120°
Driver Mean Well
Lens PC Lens
Junction Box Configuration Two-End Junction Box
Mounting Wall Mount
Luminous Efficacy 140 lm/W
Hazardous Location Rating Class I, Division 2, Groups A, B, C, D
Zone Rating Class I, Zone 2, Group IIC
Ingress Protection IP66
Impact Protection IK10
Salt Spray Test 500 hours

Potential Applications

Potential applications include compatible industrial process areas, industrial maintenance facilities, and other hazardous-location projects where the specified Class I, Division 2 or Class I, Zone 2 rating meets the site requirements. The IP66, IK10, and salt spray test specifications may also be relevant when evaluating environmental exposure and mechanical impact requirements.

Always confirm the hazardous-area classification, environmental conditions, mounting requirements, and applicable electrical codes before installation. Product suitability depends on the exact site conditions and the scope of the applicable certifications.

Frequently Asked Questions

What is the wattage and color temperature?

This model is rated at 40W and has a 5000K color temperature.

What input voltage does this light support?

The specified input voltage is 100–277V AC.

Does this fixture support dimming?

Yes. It supports 0–10V dimming with compatible controls.

What are the hazardous-location ratings?

The supplied ratings are Class I, Division 2, Groups A, B, C, and D, and Class I, Zone 2, Group IIC. Confirm the product marking and certification documentation for the intended installation.

What do IP66 and IK10 mean for this product?

IP66 and IK10 are the ingress-protection and mechanical-impact ratings specified for this model. Review the applicable test and certification records for the exact conditions covered.

Does this light provide emergency backup lighting?

The supplied information lists UL 924, but the exact scope of this standard for the model and its emergency-lighting functionality have not been confirmed. Verify the product documentation before relying on emergency operation or battery backup.

What is the salt spray test rating?

The supplied specifications state that the fixture has undergone a 500-hour salt spray test. Consult the test report for the test method and conditions.